Install Fiber Patch Cable in Ports 10/3 and 10/4

Through release 9.3, on an appliance, SD-WAN ports 10/3 and 10/4 must be connected with the provided cable, as shown in the following figure.

Note

Fiber patch cable for 10/3 and 10/4 port is applicable only to the 4000 and 5000 WANOP series appliances.

Starting with release 9.3, the patch cable is no longer required, and can be omitted if:

  • The appliance was shipped from the factory with release 9.3 or later, or
  • The appliance was shipped from the factory with release 9.3 or earlier, but you upgrade it to later version and change the default loopback in the management service (on System > Configuration > System > Configure Loopback Settings).

If you decide to eliminate the need to use loopback cable, the ports 10/3 and 10/4 are still reserved. These ports are not available for WAN optimization.

To install the patch cable

  1. Connect the LC-to-LC cable to the ports as shown in the figures above.
  2. Insert one end of the cable into port 10/3.
  3. Insert the other end of the cable into port 10/4.
Install Fiber Patch Cable in Ports 10/3 and 10/4