Product Documentation

NetScaler SD-WAN 10.0.7 Release Notes

This release note describes known issues, and fixed issues applicable to the SD-WAN software release 10.0 version 7 for the SD-WAN Standard Edition, WANOP, and Enterprise Edition appliances, and SD-WAN Center.

For information about the previous release versions, see the NetScaler SD-WAN documentation.

What’s New

NSSDW-15594: A regenerate appliance certificate upload option for SSL communication between the SD-WAN Center and SD-WAN appliance is introduced. The regenerated certificate on the MCN appliance needs to be uploaded to the SD-WAN Center for the SSL communication to work.

To regenerate appliance certificate:

  1. Navigate to Configuration > Virtual WAN > SD-WAN Center Certificates > Appliance Certificate Management. The following options are available.

    • Regenerate appliance certificate for SSL communication.
    • Download the appliance certificate.
  2. In SD-WAN Center, upload the appliance certificate by navigating to, Configuration > Network Discovery > SSL Certificate > Appliance Certificate.

    localized image

    localized image

For existing deployments upgrading to release 10.0 version 7 does not require installing the new appliance certificate on the SD-WAN center because the already installed default application certificate is not removed. However, for new deployments, and for SSL communication to work, you should install the appliance certificate to the SD-WAN Center.

Fixed issues

SDWANHELP-682 (SR# 78694883): When creating a Site the location field is not saved.

SDWANHELP-649 (SR# 78646995): Excessive Virtual Path packet retransmission is experienced with low bandwidth utilization, high loss or congestion, and less than 20 ms RTT times.

SDWANHELP-650 (SR# 78640419): On the SD-WAN 4,100 appliances, the MCN GUI is unresponsive after an upgrade to release 10.2.

SDWANHELP-698 (SR# 78744599): The SD-WAN appliance does not fail over when the LAN switch goes down.

SDWANHELP-520 (SR# 78300015): The SD-WAN appliance might crash due to invalid memory reference. The health monitoring process restarts the failed SD- WAN service automatically.

NSSDW-14516: The Audit Request from GUI is timed out when you attempt to compile large configuration file.

NSSDW-16165: Subnet added as part of region definition does not get populated in routes table.

NSSDW-17108: Selecting the first autopath group when configuring WAN Link Templates displays as “no group selected”.

Known issues

There are no known issues in release 10.0 version 7.