Product Documentation

Configuring Link Redundancy

Jan 22, 2014

To configure link redundancy

  1. In the configuration utility, on the Configuration tab, in the navigation pane, expand System and then click High Availability.
  2. On the Failover Interface Set tab, click Add.
  3. In Name, type a name for the set.
  4. In Interfaces, click Add.
  5. Under Available Interfaces, select an interface and then click the arrow to move the interface to Configured.
  6. Repeat Steps 4 and 5 for the second interface, and then click Create.

You can add as many interfaces as you need for failover between the interfaces.

To remove interfaces from the failover interface set

  1. In the configuration utility, on the Configuration tab, in the navigation pane, expand System and then click High Availability.
  2. On the Failover Interface Set tab, select a set and then click Remove.

To remove a failover interface set