This content has been machine translated dynamically.
Dieser Inhalt ist eine maschinelle Übersetzung, die dynamisch erstellt wurde. (Haftungsausschluss)
Cet article a été traduit automatiquement de manière dynamique. (Clause de non responsabilité)
Este artículo lo ha traducido una máquina de forma dinámica. (Aviso legal)
此内容已动态机器翻译。 放弃
このコンテンツは動的に機械翻訳されています。免責事項
This content has been machine translated dynamically.
This content has been machine translated dynamically.
This content has been machine translated dynamically.
This article has been machine translated.
Dieser Artikel wurde maschinell übersetzt. (Haftungsausschluss)
Ce article a été traduit automatiquement. (Clause de non responsabilité)
Este artículo ha sido traducido automáticamente. (Aviso legal)
この記事は機械翻訳されています.免責事項
이 기사는 기계 번역되었습니다.
Este artigo foi traduzido automaticamente.
这篇文章已经过机器翻译.放弃
Translation failed!
Configuring NSVLAN
NSVLAN is a VLAN to which the NetScaler management IP (NSIP) address’s subnet is bound. The NSIP subnet is available only on interfaces that are associated with NSVLAN. By default, NSVLAN is VLAN1, but you can designate a different VLAN as NSVLAN. If you do so, you must reboot the NetScaler appliance for the change to take effect. After the reboot, NSIP subnet traffic is restricted to the new NSVLAN.
The traffic from the NetScaler IP subnet can be tagged (802.1q) with the VLAN ID specified for NSVLAN. You must configure the attached switch interface to tag and allow this same VLAN ID on the connected interface. If you remove your NSVLAN configuration, the NSIP subnet is automatically bound to VLAN1, restoring the default NSVLAN.
To configure NSVLAN by using the NetScaler command line:
At the command prompt, type:
-
set ns config -nsvlan <positive_integer> -ifnum <interface_name> … [-tagged (YES|NO)]
-
show ns config
Note: The configuration takes effect after the NetScaler appliance is rebooted.
Example:
> set ns config -nsvlan 300 -ifnum 1/1 1/2 1/3 -tagged NO
Done
> save config
Done
To restore the default NSVLAN configuration by using the NetScaler command line:
At the command prompt, type:
- unset ns config -nsvlan
- show ns config
Example:
> unset ns config -nsvlan
Done
To configure NSVLAN by using the NetScaler GUI:
Navigate to System > Settings, in the Settings group, click Change NSVLAN Settings.
Setting the MTU on the NSVLAN
By default, the MTU of the NSVLAN is set to 1500 bytes. You can modify this setting to optimize throuhput and network performance. For example, you can configure the NSVLAN to process jumbo frames.
To set the MTU of the NSVLAN by using the NetScaler command line:
At the command prompt, type:
- set vlan <id> -mtu <positive_integer>
- show vlan <id>
To set the MTU of the NSVLAN by using the NetScaler GUI:
Navigate to System > Network > VLANs, open the NSVLAN, and set the Maximum Transmission Unit parameter.
Sample configuration:
In the following sample configuration, VLAN 100 is the NSVLAN.
> set ns config -nsvlan 100 -ifnum 1/1 -tagged no
Warning: The configuration must be saved and the system rebooted for these settings to take effect
> set vlan 100 -mtu 1600
Done
> sh vlan
1) VLAN ID: 1
Link-local IPv6 addr:
fe80::947b:52ff:fead:12d5/64
Interfaces : 1/2 LO/1
2) VLAN ID: 100 VLAN Alias Name:
MTU: 1600
Interfaces : 1/1
IPs :
10.102.53.114 Mask: 255.255.255.0
Done
> save config
Done
Configuring NSVLAN
Share
Citrix Preview Documentation
This Preview product documentation is Citrix Confidential.
You agree to hold this documentation confidential pursuant to the terms of your Citrix Beta/Tech Preview Agreement.
The development, release and timing of any features or functionality described in the Preview documentation remains at our sole discretion and are subject to change without notice or consultation.
The documentation is for informational purposes only and is not a commitment, promise or legal obligation to deliver any material, code or functionality and should not be relied upon in making Citrix product purchase decisions.
If you do not agree, select Do Not Agree to exit.