Hardware health attributes
Operating ranges for Citrix ADC hardware platforms vary for different attributes.
Note: Use the stat system -detail
command to display the current values of the attributes.
Health attributes for MPX 5500/7500/9700/9700 10G platforms
The following tables list the health attributes and their recommended value ranges.
Health attributes/Platform | SNMP Alarm Support | MPX 5500/5600 | MPX 7500/9500 | MPX 9700/10500/12500/15500 | MPX 9700/10500/ 12500/15500 10G |
---|---|---|---|---|---|
CPU 0 core (Volts) | No | 0.97–1.5 | 1–1.5 | 1–1.5 | 1–1.5 |
CPU 1 core (Volts) | No | 0.97–1.5 | 1–1.5 | 1–1.5 | 1–1.5 |
Main 3.3 V Supply (Volts) | Yes | 3.2–3.6 | 3.2–3.54 | 3.2–3.54 | 3.2–3.55 |
Standby 3.3 V Supply (Volts) | Yes | 3.2–3.6 | 3.2–3.54 | 3.2–3.54 | 3.2–3.55 |
+5.0 V Supply (Volts) | No | 4.8–5.2 | 4.8–5.2 | 4.8–5.2 | 4.8–5.2 |
+12.0 V Supply (Volts) | No | 11.5–12.35 | 11.52–12.35 | 11.5–12.31 | 11.8–12.35 |
-12.0 V Supply (Volts) | No | - NA - | - NA - | - NA - | - NA - |
Battery (Volts) | No | 3–3.5 | 2.85–3.5 | 2.85–3.5 | 2.85–3.5 |
Intel CPU Vtt Power (Volts) | No | 1–1.2 | 1–1.2 | 1–1.2 | 1–1.2 |
5 V Standby (Volts) | No | 4.9–5.2 | 4.9–5.2 | 4.9–5.2 | 4.9–5.2 |
Voltage Sensor2(Volts) | No | 1.2–2 | 1.2–2 | 1.2–2 | 1–1.8 |
CPU Fan 0 Speed (RPM) | Yes | 3000–16000 | 3000–16000 | 3000–10000 | 3000–16000 |
CPU Fan 1 Speed (RPM) | Yes | 3000–16000 | 3000–16000 | 3000–16000 | 3000–16000 |
System Fan Speed (RPM) | Yes | 900–15000 | 900–13000 | 900–10000 | 900–9000 |
System Fan 1 Speed (RPM) | No | 900–15000 | 900–15000 | 900–10000 | 900–8000 |
System Fan 2 Speed (RPM) | No | 900–15000 | 900–15000 | 900–10000 | 900–10000 |
CPU 1 Temperature | Yes | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) |
CPU 0 Temperature | Yes | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) |
Internal Temperature | Yes | 19–50 (Celsius), 66.2–122 (Fahrenheit) | 19–50 (Celsius), 66.2–122 (Fahrenheit) | 19–50 (Celsius), 66.2–122 (Fahrenheit) | 19–50 (Celsius), 66.2–122 (Fahrenheit) |
Power Supply 1 Status | Yes | Not supported | Normal | Normal | Normal |
Power Supply 2 Status | Yes | Not supported | Normal | Normal | Normal |
Health attributes for MPX 5550/8005/11500/17500/17550 platforms
The following tables list the health attributes and their recommended value ranges.
Health attributes/Platform | SNMP Alarm Support | MPX 17500/19500/21500 | MPX 11500/13500/14500/16500/ 18500/20500 | MPX 17550/19550/20550/21550 | MPX8005/8015/8200/8400/8600/8800 | MPX 5550/5650/5750 |
---|---|---|---|---|---|---|
CPU 0 core (Volts) | No | 0.99–1.5 | 0.95–1.5 | 0.95–1.5 | - NA - | - NA - |
CPU 1 core (Volts) | No | 0.99–1.5 | 0.95–1.56 | 0.95–1.5 | - NA - | - NA - |
Main 3.3 V Supply (Volts) | Yes | 3.19–3.55 | 3.19–3.55 | 3.18–3.55 | 3.14–3.47 | 3.14–3.47 |
Standby 3.3 V Supply (Volts) | Yes | 3.2–3.55 | 3.1–3.55 | 3.1–3.55 | 3.14–3.47 | 3.14–3.47 |
+5.0 V Supply (Volts) | No | 4.8–5.2 | 4.8–6.24 | 4.8–5.2 | 4.75–5.25 | 4.75–5.25 |
+12.0 V Supply (Volts) | No | 11.5–12.35 | 11.8–12.35 | 11.5–12.35 | 11.40–12.60 | 11.40–12.60 |
-12.0 V Supply (Volts) | No | - NA - | - NA - | - NA - | (-10.80)–(-13.20) | (-10.80)–(-13.20) |
Battery (Volts) | No | 2.85–3.37 | 3–3.5 | 2.8–3.5 | > 2.5 | > 2.5 |
Intel CPU Vtt Power (Volts) | No | 1–1.2 | 1–1.2 | 1–1.2 | - NA - | - NA - |
5 V Standby (Volts) | No | 4.88–5.2 | 4.8–5.25 | 4.9–5.3 | - NA - | - NA - |
Voltage Sensor2 (Volts) | No | 1.4–5.2 | 1.4–6.24 | 1.4–5.2 | 3.14–3.47 | 3.14–3.47 |
CPU Fan 0 Speed (RPM) | Yes | 3000–16000 | 3000–16000 | 3000–16000 | > 5500 | > 5500 |
CPU Fan 1 Speed (RPM) | Yes | 3000–16000 | 3000–16000 | 3000–16000 | > 5500 | > 5500 |
System Fan Speed (RPM) | Yes | 900–15000 | 900–15000 | 900–15000 | > 5500 | > 5500 |
System Fan 1 Speed (RPM) | No | 900–15000 | 900–15000 | 900–16000 | > 5500 | > 5500 |
System Fan 2 Speed (RPM) | No | 900–15000 | 900–15000 | 900–16000 | > 5500 | > 5500 |
CPU 0 Temperature | Yes | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | < 85 (Celsius), < 185 (Fahrenheit) | < 85 (Celsius), < 185 (Fahrenheit) |
CPU 1 Temperature | Yes | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | 24–90 (Celsius), 75.2–194 (Fahrenheit) | - NA - | - NA - |
Internal Temperature | Yes | 19–50 (Celsius), 66.2–122 (Fahrenheit) | 19–50 (Celsius), 66.2–122 (Fahrenheit) | 19–50 (Celsius), 66.2–122 (Fahrenheit) | < 55 (Celsius), < 131 (Fahrenheit) | < 55 (Celsius), < 131 (Fahrenheit) |
Power Supply 1 Status | Yes | Normal | Normal | Normal | Normal | Not supported |
Power Supply 2 Status | Yes | Normal | Normal | Normal | Normal, if both power supplies are installed | Not supported |
Health attributes for the MPX 14000 platform
The following table lists the health attributes for the MPX 14000 platform.
Health Attribute | Recommended Range |
---|---|
CPU 0 core (Volts) | 0.85–0.91 |
CPU 1 core Volt | 0.85–0.93 |
Main 3.3 V Supply (Volts) | 3.31–3.36 |
Standby 3.3 V Supply (Volts) | 3.26–3.31 |
+5.0 V Supply (Volts) | 4.99–5.06 |
+12.0 V Supply (Volts) | 11.98–12.08 |
Battery Voltage | 3.02–3.12 |
Internal CPU Vtt Power | 0.99–1.01 |
CPU Fan 0 Speed (RPM) | 1875–4350 |
CPU Fan 1 Speed (RPM) | 1875–4200 |
System Fan Speed (RPM) | 1875–4350 |
System Fan 1 Speed (RPM) | 1875–4275 |
System Fan 2 Speed (RPM) | 1875–4200 |
CPU 0 Temperature (Celsius) | 33–43 |
CPU 1 Temperature (Celsius) | 35–45 |
Internal Temperature (Celsius) | 28–38 |
Power Supply 1 Status | NORMAL |
Power Supply 2 Status | NORMAL |
Health attributes for the MPX 22040 platform
The following table lists the health attributes for the MPX 22040 platform.
Health attribute | Unit | Lower Non-Recoverable | Lower Critical | Lower Non-Critical | Upper Non-Critical | Upper Critical | Upper Non-Recoverable |
---|---|---|---|---|---|---|---|
CPU1 Temp | degrees C | 0.000 | 0.000 | 0.000 | 90.000 | 93.000 | 95.000 |
CPU2 Temp | degrees C | 0.000 | 0.000 | 0.000 | 90.000 | 93.000 | 95.000 |
System Temp | degrees C | -9.000 | -7.000 | -5.000 | 80.000 | 85.000 | 90.000 |
Peripheral Temp | degrees C | -9.000 | -7.000 | -5.000 | 80.000 | 85.000 | 90.000 |
PCH Temp | degrees C | -11.000 | -8.000 | -5.000 | 90.000 | 95.000 | 100.000 |
FPC_Temp 1 | degrees C | - NA - | - NA - | - NA - | 66.000 | 70.000 | 75.000 |
FPC_Temp 2 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
FPC_Temp 3 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
HDDBP_Temp 1 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
HDDBP_Temp 2 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
FAN 1 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 2 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 3 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 4 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 5 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 6 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 7 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 8 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
PS_1 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_1 FAN | RPM | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_1 Temp | degrees C | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_2 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_2 FAN | RPM | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_2 Temp | degrees C | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_3 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_3 FAN | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
PS_3 Temp | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
PS_4 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_4 FAN | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
PS_4 Temp | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
FPC Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
VTT | Volts | 0.816 | 0.864 | 0.912 | 1.344 | 1.392 | 1.440 |
CPU1 Vcore | Volts | 0.480 | 0.512 | 0.544 | 1.488 | 1.520 | 1.552 |
CPU2 Vcore | Volts | 0.480 | 0.512 | 0.544 | 1.488 | 1.520 | 1.552 |
VDIMM AB | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
VDIMM CD | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
VDIMM EF | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
VDIMM GH | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
+1.5 V | Volts | 1.248 | 1.296 | 1.344 | 1.648 | 1.696 | 1.744 |
3.3 V | Volts | 2.640 | 2.784 | 2.928 | 3.648 | 3.792 | 3.936 |
+3.3VSB | Volts | 2.640 | 2.784 | 2.928 | 3.648 | 3.792 | 3.936 |
5 V | Volts | 4.096 | 4.288 | 4.480 | 5.504 | 5.696 | 6.912 |
12 V | Volts | 10.176 | 10.494 | 10.812 | 13.250 | 13.568 | 13.886 |
VBAT | Volts | 2.400 | 2.544 | 2.688 | 3.312 | 3.456 | 3.600 |
Health attributes for MPX 24100 platform
The following table lists the health attributes for MPX 24100/24150.
Health attribute | Unit | Lower Non-Recoverable | Lower Critical | Lower Non-Critical | Upper Non-Critical | Upper Critical | Upper Non-Recoverable |
---|---|---|---|---|---|---|---|
CPU1 Temp | degrees C | 0.000 | 0.000 | 0.000 | 90.000 | 93.000 | 95.000 |
CPU2 Temp | degrees C | 0.000 | 0.000 | 0.000 | 90.000 | 93.000 | 95.000 |
System Temp | degrees C | -9.000 | -7.000 | -5.000 | 80.000 | 85.000 | 90.000 |
Peripheral Temp | degrees C | -9.000 | -7.000 | -5.000 | 80.000 | 85.000 | 90.000 |
PCH Temp | degrees C | -11.000 | -8.000 | -5.000 | 90.000 | 95.000 | 100.000 |
FPC_Temp 1 | degrees C | - NA - | - NA - | - NA - | 66.000 | 70.000 | 75.000 |
FPC_Temp 2 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
FPC_Temp 3 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
HDDBP_Temp 1 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
HDDBP_Temp 2 | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
FAN 1 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 2 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 3 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 4 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 5 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 6 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 7 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
FAN 8 | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
PS_1 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_1 FAN | RPM | - NA - | 1980.000 | - NA - | - NA - | - NA - | - NA - |
PS_1 Temp | degrees C | - NA - | - NA - | - NA - | 72.000 | 76.000 | 82.000 |
PS_2 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_2 FAN | RPM | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_2 Temp | degrees C | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_3 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_3 FAN | RPM | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_3 Temp | degrees C | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_4 Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_4 FAN | RPM | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
PS_4 Temp | degrees C | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
FPC Status | discrete | - NA - | - NA - | - NA - | - NA - | - NA - | - NA - |
VTT | Volts | 0.816 | 0.864 | 0.912 | 1.344 | 1.392 | 1.440 |
CPU1 Vcore | Volts | 0.480 | 0.512 | 0.544 | 1.488 | 1.520 | 1.552 |
CPU2 Vcore | Volts | 0.480 | 0.512 | 0.544 | 1.488 | 1.520 | 1.552 |
VDIMM AB | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
VDIMM CD | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
VDIMM EF | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
VDIMM GH | Volts | 1.104 | 1.152 | 1.200 | 1.648 | 1.696 | 1.744 |
+1.5 V | Volts | 1.248 | 1.296 | 1.344 | 1.648 | 1.696 | 1.744 |
3.3 V | Volts | 2.640 | 2.784 | 2.928 | 3.648 | 3.792 | 3.936 |
+3.3VSB | Volts | 2.640 | 2.784 | 2.928 | 3.648 | 3.792 | 3.936 |
5 V | Volts | 4.096 | 4.288 | 4.480 | 5.504 | 5.696 | 6.912 |
12 V | Volts | 10.176 | 10.494 | 10.812 | 13.250 | 13.568 | 13.886 |
VBAT | Volts | 2.400 | 2.544 | 2.688 | 3.312 | 3.456 | 3.600 |
Health attributes for the MPX 5900 platform
The following table lists the health attributes for the MPX 5900 platform.
Health Attribute | Recommended Range |
---|---|
CPU 0 core (Volts) | 1.77–1.81 |
Main 3.3 V Supply (Volts) | 3.25–3.32 |
Standby 3.3 V Supply (Volts) | 3.27–3.32 |
+5.0 V Supply (Volts) | 4.84–4.95 |
+12.0 V Supply (Volts) | 11.75–12.00 |
Battery (Volts) | 3.02–3.16 |
5 V Standby (Volts) | 5.05–5.13 |
CPU Fan 0 Speed (RPM) | 6900–8700 |
CPU Fan 1 Speed (RPM) | 6500–8500 |
System Fan Speed (RPM) | 6700–8600 |
System Fan 1 Speed (RPM) | 6600–8500 |
System Fan 2 Speed (RPM) | 6700–8500 |
CPU 0 Temperature (Celsius) | 39–44 |
CPU 1 Temperature (Celsius) | 35–45 |
Internal Temperature (Celsius) | 31–38 |
Power Supply 1 Status | NORMAL |
Power Supply 2 Status | NOT PRESENT–NORMAL |
Health attributes for the MPX 8900 platform
The following table lists the health attributes for the MPX 8900 platform.
Health Attribute | Recommended Range |
---|---|
CPU 0 core (Volts) | 1.77–1.81 |
Main 3.3 V Supply (Volts) | 3.25–3.32 |
Standby 3.3 V Supply (Volts) | 3.25–3.32 |
+5.0 V Supply (Volts) | 4.84–4.95 |
+12.0 V Supply (Volts) | 11.75–12.00 |
Battery (Volts) | 3.02–3.13 |
5 V Standby (Volts) | 5.05–5.16 |
CPU Fan 0 Speed (RPM) | 6600–12600 |
CPU Fan 1 Speed (RPM) | 6300–12200 |
System Fan Speed (RPM) | 6700–8600 |
System Fan 1 Speed (RPM) | 6600–8500 |
System Fan 2 Speed (RPM) | 6700–8500 |
CPU 0 Temperature (Celsius) | 40–57 |
CPU 1 Temperature (Celsius) | 35–45 |
Internal Temperature (Celsius) | 30–49 |
Power Supply 1 Status | NORMAL |
Power Supply 2 Status | NOT PRESENT–NORMAL |
Health attributes for the MPX 15000 and MPX 26000 platforms
The following table lists the health attributes for the MPX 15000 and MPX 26000 platforms.
Health Attribute | Unit | Minimum value | Nominal value | Maximum value |
---|---|---|---|---|
CPU 0 Core Voltage | Volt | 1.47 | 1.82 | 1.835 |
CPU 1 Core Voltage | Volt | 1.47 | 1.82 | 1.835 |
3_3VCC | Volt | 3.12 | 3.30 | 3.48 |
3_3VSB | Volt | 3.12 | 3.30 | 3.48 |
5VCC | Volt | 4.72 | 5.00 | 5.28 |
p12V | Volt | 11.33 | 12.00 | 12.67 |
VBAT | Volt | 2.75 | 3.00 | 3.200 |
Vtt | -NA- | -NA- | -NA- | -NA- |
5VSB | Volt | 4.72 | 5.00 | 5.28 |
Voltage Sensor2 | -NA- | -NA- | -NA- | -NA- |
CPU Fan 0 Speed | RPM | 1500 | -NA- | 7500 |
CPU Fan 1 Speed | RPM | 1500 | -NA- | 7500 |
System Fan Speed | RPM | 1500 | -NA- | 7500 |
System Fan 1 Speed | RPM | 1500 | -NA- | 7500 |
System Fan 2 Speed | RPM | 1500 | -NA- | 7500 |
Fan 0 Speed | RPM | 1500 | -NA- | 7500 |
CPU 0 Temp | Celsius | 0 | -NA- | 85 |
CPU 1 Temp | Celsius | 0 | -NA- | 85 |
Internal Temp | Celsius | 0 | -NA- | 80 |
In this article
- Health attributes for MPX 5500/7500/9700/9700 10G platforms
- Health attributes for MPX 5550/8005/11500/17500/17550 platforms
- Health attributes for the MPX 14000 platform
- Health attributes for the MPX 22040 platform
- Health attributes for MPX 24100 platform
- Health attributes for the MPX 5900 platform
- Health attributes for the MPX 8900 platform
- Health attributes for the MPX 15000 and MPX 26000 platforms