ADC

Set a timeout value for idle client connections

You can configure the service with a time-out value to terminate any idle client connections when the configured time elapses. If the client is idle during the configured time, the NetScaler appliance closes the client connection.

To set a timeout value for idle client connections by using the CLI

At the command prompt, type:

set service <name> -cltTimeout <Value>
<!--NeedCopy-->

Example:

set service Service-HTTP-1 -cltTimeout 100
<!--NeedCopy-->

To set a timeout value for idle client connections by using the GUI

  1. Navigate to Traffic Management > Load Balancing > Services, and open a service.
  2. In Advanced Settings, select Thresholds & Timeouts, and select Client Idle Time-out.
Set a timeout value for idle client connections