This table lists problems that can occur after you install or update Scout, or when devices download their software, and how to solve them:
| Error message / problem | Reason | Solution |
|---|---|---|
| Scout desktop icons are not displayed correctly. | Desktop icons are cached by Windows. This may lead to the fact that after you update Scout, new icons are not displayed correctly. | Delete the Windows icon cache. Please refer to the relevant documentation. |
| File access error while checking HTTP/FTP server (error number = 404) | Possibly caused by missing MIME type entries for the used file extensions on the web server | In the MIME type settings of the web server, add the file extensions of the container folders and assign them to the MIME types in the following table. For Microsoft Internet Information Services (IIS), see Example of publishing the containers with IIS in the UniconOS Management Board guide. |
| Devices install an image that Software has taken out of the container folder. | The web server delivers the image file from its cache. | Turn off caching for image files (.idf) and signature files (.sig) on the web server. For IIS, see Example of publishing the containers with IIS in the UniconOS Management Board guide. |
For firmware updates, the web server must deliver the packages, images and signature files of the container folders with these MIME types:
| Extension | MIME type |
|---|---|
| .epm | application/octet-stream |
| .fpm | application/octet-stream |
| .idf | application/octet-stream |
| .sig | application/octet-stream |
Don't assign a MIME type to all extensions (
.*) instead, because the web server would then deliver every file of the container folders.
The following additional assignments might become necessary:
| Extension | MIME type | Description |
|---|---|---|
| .bin | application/octet-stream | BIOS update via Scout |
| .bup | text/plain | BIOS update via Scout |
| .cab | application/vnd.ms-cab-compressed | UEFI update via Scout |
| .gz | application/x-gzip | Migration from eLux® RP 6 to UniconOS 7: the file migrationfiles-<version>.tar.gz in the container folder |
| .mee | text/plain | Migration of eLux RP 5 devices to eLux RP 6 with whitelist. Different images depending on the hardware model (/en-us/unicon-elux-scout/2611/admin_guides/scout/setup/firmware/firmware_macro_hardware.html) |
| .rdf | text/plain | Migration from eLux RP 6 to UniconOS 7: the file recovery_systemEFI.rdf in the container folder |
| .udf | text/plain | UEFI updates in analogy to firmware updates (from Scout 15 2107 and eLux RP 6 2107) |
Troubleshooting for an installation with Microsoft SQL Server
Scout keeps its license data in the Scout database. When Scout Server starts with a restored or copied database, it binds the license data to this database by itself. This also works if the database is on another SQL Server. You don't need to unlock the database. For this step, Scout Server must be able to read the ID of the database:
| Error message | Reason | Solution |
|---|---|---|
Scout Server stops right after it starts. eluxd.log contains Database GUID is different and the database's own GUID is blank. |
Scout Server can't read the ID of the Scout database. Without this ID, it can't bind the license data to the database. | Contact Citrix® Support. |
If Scout Server can't connect to the Scout database when it starts, for example because SQL Server isn't running yet after a restart of the computer, Scout Server waits for the database for several minutes. If the database doesn't answer in this time, Scout Server stops:
| Error message | Reason | Solution |
|---|---|---|
Scout Server stops during its start. The Windows Application log shows Scout Server stopped during start-up: no database connection could be opened (exit code 1017). |
Scout Server can't connect to the Scout database. | Make sure that SQL Server runs and that Scout Server can reach it. Then start the Scout Server service. |